SIGA (Switzerland) and Pro Clima (Germany) are the two best-known airtightness systems used on UK passive house, timber frame and retrofit projects. Both are high-quality systems. This guide maps the equivalent products so you can choose and order a complete kit.
The golden rule: pick one system
Each manufacturer tests its membranes, tapes, primers and sealants to work together. Use one brand throughout the airtight layer: membrane, tape, window tape and grommets. That way the components are compatible and you can rely on the manufacturer's system guidance.
Equivalent products
| Job | SIGA | Pro Clima |
|---|---|---|
| Internal vapour control layer (humidity-variable) | Majrex 200 | Intello Plus, DB+, DA |
| Internal vapour control layer (fixed value) | Majpell 5 | – |
| Roofing underlay / breather membrane | Majcoat 200 SOB | Solitex Plus |
| Facade membrane | – | Solitex Fronta WA |
| Main airtight tape (membrane overlaps and joints) | Sicrall, Rissan | Tescon Vana |
| Internal window/door connection tape | Fentrim 20, Fentrim IS 20 | Contega Solido SL |
| External window/door and exterior joints | Wigluv 60 | Contega Solido EXO |
| Corner tape | – | Tescon Profil |
| Double-sided tape | Twinet 20 | – |
| Membrane-to-masonry sealant | – | Orcon F |
| Primer for dusty or porous substrates | – | Tescon Primer RP, Tescon Sprimer |
| Cable and pipe grommets | – | Kaflex Mono/Duo, Roflex 30/50/100 |
"–" means we don't currently list an equivalent in that range. Ask us if you need one.
Which should I choose?
- Follow the specification. If your architect, Passivhaus designer or warranty provider has named a system, use it.
- Window installation: SIGA's Fentrim range is pre-folded and plaster-compatible, which makes it popular for window fitting into masonry.
- Complete kit from one brand: our Pro Clima range covers sealant, primers and service grommets as well as membranes and tapes.
- Need a quantity? The Airtightness Kit Estimator works out membrane rolls and tape from your floor area.
Installation tips
- Overlap membranes and tape every overlap, junction and penetration.
- Substrates must be clean, dry and free of dust. Prime porous or dusty surfaces before taping.
- Press tapes down firmly along their full length.
- Seal every service penetration with a grommet rather than tape alone where possible.
- Test the building (blower door) before the airtight layer is covered.